| Model |
Mars-5G1-LE |
Mars-6G1-LE |
Mars-8G1-LE |
Mars-10G1-LE |
Mars-12G1-LE |
Mars-14G1-LE |
| Battery Input |
| Battery Type |
Lead-acid or Li-Lon |
| Battery Voltage Range (V) |
40-60 |
| Max. Charge Current (A) |
120 |
130 |
200 |
220 |
250 |
280 |
| Max. Discharge Current (A) |
120 |
130 |
200 |
220 |
250 |
280 |
| Charging Curve |
3 Stages/Equalization |
| External Temperature Sensor |
Optional |
| Charging Strategy for Li-Ion Battery |
Self-Adaption to BMS |
| PV String Input |
| Max. DC Input Power (W) |
7,500 |
9,000 |
12,000 |
15,000 |
18,000 |
20,000 |
| PV Input Voltage (V) |
650(160~800) |
| MPPT Range (V) |
200~700 |
| Full Load DC Voltage Range (V) |
260~650 |
| Start-up Voltage (V) |
160 |
| PV Input Current (A) |
17+17 |
17+17 |
17+17 |
26+17 |
26+17 |
26+17 |
| Max. PV Isc (A) |
20+20 |
20+20 |
20+20 |
34+20 |
34+20 |
34+20 |
| No. of MPPT Trackers |
2 |
| No. of Strings per MPPT Trackers |
1+1 |
1+1 |
1+1 |
2+1 |
2+1 |
2+1 |
| AC Output |
| Rated AC Output and UPS Power (W) |
5,000 |
6,000 |
8,000 |
10,000 |
12,000 |
14,000 |
| Max. AC Output Power (W) |
6,000 |
7,200 |
9,600 |
12,000 |
13,200 |
15,400 |
| Peak PoWer(off grid) |
2 times of rated power, 10s |
1.8 times of rated power, 10s |
| AC Output Rated Current (A) |
7.6/7.3 |
9.1/8.7 |
12.1/11.6 |
15.2/14.5 |
18.2/17.4 |
21.1/20.3 |
| Max. AC Current (A) |
11.4/10.9 |
13.6/13 |
18.2/17.4 |
22.7/21.7 |
27.3/26.1 |
27.6/26.4 |
| Max. Continuous AC Passthrough (A) |
30 |
30 |
30 |
50 |
50 |
50 |
| Power Factor |
0.8 leading to 0.8 lagging |
| Output Frequency and Voltage (V) |
50/60Hz, 380/400Vac(Triple phase) |
| Grid Type |
Three phase |
| Current Harmonic Distortion |
THD<3%(Linear load<1.5%) |
| Efficiency |
| Max. Efficiency |
97.90% |
| Euro Efficiency |
97.00% |
| MPPT Efficiency |
99.90% |
| Protection |
| Integrated |
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation
Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection |
| PV Arc Fault Detection |
Optional |
| Output Over Voltage Protection |
DC Type II/AC Type III |
| Certifications and Standards |
| Grid Regulation |
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699,C10-11 |
| Safety Regulation |
IEC/EN62109-1, IEC/EN62109-2 |
| EMC |
IEC/EN 61000-6-1,IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
| General Data |
| Operating Temperature Range (℃) |
-45~60,>45 Derating |
| Cooling |
Smart Cooling |
| Noise (dB) |
≤45 |
| Communication with BMS |
RS485, CAN |
| Weight (kg) |
38 |
40 |
42 |
44 |
44 |
45 |
| Dimensions (mm) |
510Wx630Hx290D |
| Protection Degree |
IP65 |
| Installation Style |