Model |
Jup-3G1-LE
Jup-3G2-LE |
Jup-5G1-LE
Jup-5G2-LE |
Jup-6G1-LE
Jup-6G2-LE |
Jup-8G1-LE
Jup-8G2-LE |
Jup-10G1-LE
Jup-10G2-LE |
Battery Input Data |
Battery Type |
Lead-acid or Li-ion |
Battery Voltage Range (V) |
40-60 |
Max. Charge Current (A) |
70 |
120 |
140 |
190 |
210 |
Max. Discharge Current (A) |
70 |
120 |
140 |
190 |
210 |
Charging Curve |
3 Stages/Equalization |
External Temperature Sensor |
Optional |
Charging Strategy for Li-Ion Battery |
Self-Adaption to BMS |
PV String Input Data |
Max. DC Input Power (W) |
4500 |
7500 |
9000 |
12000 |
15000 |
PV Input Voltage (V) |
370(125~500) |
MPPT Range (V) |
150~425 |
Start-up Voltage (V) |
120 |
PV Input Current (A) |
17 |
17+17 |
17+17 |
26+26 |
26+26 |
Max. PV ISC (A) |
20 |
20+20 |
20+20 |
34+34 |
34+34 |
No. of MPPT Trackers |
1 |
2 |
2 |
2 |
2 |
No. of String Per MPPT Tracker |
1 |
1+1 |
1+1 |
2+2 |
2+2 |
AC Output Data |
Rated AC Output Power and UPS Power (W) |
3000 |
5000 |
6000 |
8000 |
10000 |
Max. AC Output Power (W) |
3600 |
6200 |
7200 |
9600 |
12000 |
Peak Power(off grid) |
2 times of rated power, 10s |
1.8 times of rated power, 10s |
AC Output Rated Current (A) |
13.65/13.05 |
22.7/21.7 |
27.3/26.1 |
34.5/33 |
45.5/43.5 |
Max. AC Current (A) |
25/14.35 |
25/23.9 |
30/28.7 |
40/38.3 |
50.0/47.8 |
Max. Continuous AC Passthrough (A) |
40 |
40 |
40 |
50 |
60 |
Power Factor |
0.8 leading to 0.8 lagging |
Output Frequency and Voltage |
50/60Hz,220/230Vac(single phase) |
Grid Type |
single phase |
Current Harmonic Distortion |
THD<3%(Linear load <1.5%) |
Efficiency |
Max. Efficiency |
97.90% |
Euro Efficiency |
97.00% |
MPPT Efficiency |
99.90% |
Protection |
Integrated |
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection |
PV ARC Fault Detection |
Optional |
Output Over Voltage Protection |
DC Type II/AC Type III |
Certification and Standards |
Grid Regulation |
CEI 0-21,VDE-AR-N 4105,NRS 097,IEC61727,G99,G98,VDE 0126-1-1,RD 1699,C10-11 |
EMC/Safety Regulation |
IEC/EN 62109-1 IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
General Data |
Operating Temperature Range(℃) |
-45~60,>45 Derating |
Cooling |
Smart cooling |
Noise(dB) |
≤45 |
Communication with BMS |
CAN, RS485 34 |
Weight (kg) |
34 |
Dimensions (mm) |
514W ×749H ×291D |
Protection Degree |
IP65 |
Installation Style |
Wall-mounted |